IconEnglish
MORE INFORMATION

Signal switches, standard

Materials:
Brass, nickel-plated brass, plastic, gaskets: NBR


Switching time
:
3 ms


Electrical connection loads:

Max. 2 A, 0 - 48 V DC, 250 V AC


Power consumption:
DC: 5 W, AC 10 VA


Protection class:

IP 40


Operation
:
A signal coupling takes over the function of a limit switch (pneumatic or electrical signal). The screw is screwed into the inlet hole of a cylinder and scans the working pressure of the cylinder. When there is no more pressure on the clutch, the clutch switches from (P) 1 to (S) 5.


Please note:

Signal couplings detect the reaching of the end position only by a loss of pressure. However, this pressure loss can also occur if the cylinder in its control range is blocked. If there is a risk of such a blockage, we recommend the use of pneumatic cylinder switches that react directly to the magnetic field of a magnetic piston.


Advantages
:
• Purely pneumatic control device, no electrical energy required,
• Easy installation,
• Compact shape