IconEnglish

2/2 way solenoid valves made of brass, Eco-line - indirect

MORE INFORMATION

2/2 way solenoid valves made of brass, Eco-line - indirect

Materials

 

Housing: Brass, internal parts: Brass / stainless steel, seal: NBR (Types with G 1/8 "and G 1/4": FKM)

 

 

 

Temperature range:

 

-10 ° C to max. +85 ° C (types with G 1/8 "and G 1/4": -10 ° C to max. +130 ° C), environment: -10 ° C to max. +50 ° C

 

 

 

Media:

 

Compressed air, neutral gases, water, neutral light media, heating oil, other media on request

 

 

 

Installation position:

 

with standing magnet

 

 

 

Tensions:

 

Standard: 24 V =, 230 V AC, if desired: other voltages

 

 

 

Protection class:

 

IP 65

 

Control:

 

Indirect or servo-controlled solenoid valves use the differential pressure of the medium to open or close. The minimum pressure difference is usually 0.5 bar. Because the fluid pressure is used, a relatively small coil can still control a large membrane and therefore a high flow.

 

Optional on request

 

FKM seal (-10 ° C to max. +130 ° C) -V, EPDM seal for air and hot water (-10 ° C to max. +120 ° C) -EP, EX-protected ** -EX

 

 

 

Information:

 

These valves are supplied with coils and plugs!

 

 

 

Pay attention:

 

Servo-controlled valves require a pressure difference between the valve inlet and outlet for opening or closing. The pressure difference is displayed as the minimum pressure. If pressure compensation occurs in the valve, possibly because little or no consumption is made at the valve outlet, the valve no longer works (opens or closes reliably)

 

 

 

* Water flow rate at +20 ° C, 1 bar pressure in valve inlet, free spout. Flow rate for air [l / min] approx. 13.4 x kv x P Input, when P Output <P Input / 2 (P Input and P Output are absolute values ​​in bar.), ** indicate protection class, only NC valves

 

Documents for 2/2 way solenoid valves made of brass, Eco-line - indirect

icon2-2 solenoid valve NC

MORE INFORMATION

Solenoid valve 2-2 brass indirect G3-8Solenoid valve 2-2 brass indirect G1-2Solenoid valve 2-2 brass indirect G3-4Solenoid valve 2-2 brass indirect G1Solenoid valve 2-2 brass indirect G1 1-2Solenoid valve 2-2 brass indirect G2Solenoid valve 2-2 brass indirect G1 1-4Solenoid valve 2-2 brass indirect NC IMV22NC12EM230Solenoid valve 2-2 brass indirect NC IMV22NC34EM230Solenoid valve 2-2 brass indirect NC IMV22NC1EM230Solenoid valve 2-2 brass indirect NC IMV22NC112EM230Solenoid valve 2-2 brass indirect NC IMV22NC114EM230Solenoid valve 2-2 brass indirect NC IMV22NC2EM230Solenoid valve 2-2 brass indirect NC IMV22NC112FM230
FILTERS

Thread

Seal

Minimum temperature (°C)

Maximum temperature (°C)

Voltage

kv value (m3/h)

Orifice (DN) (mm)

Loading, Please wait.

Even geduld a.u.b. uw gegevens worden opgehaald.

Loading

All statements are intended as non-binding guidelines! We are not liable for data selection not confirmed in writing. Pressure data, unless stated otherwise, relate to liquids from group II at +20 C.

HafnerFHTcmaticVacuproVan deurne