STANDARD SUPPLIED WITH PLUG
Materials:
Housing: Brass
Internal parts: Brass / Stainless steel
Seals: FKM or EPDM
Function:
Solenoid valve 2/2-way
Pilot-operated, normally closed (NC)
Nominal diameter (DN):
From 13 mm to 50 mm
Thread:
G 3/8″, G 1/2″, G 3/4″, G 1″, G 1 1/4″, G 1 1/2″ and G 2″
Temperature range:
FKM: -10 °C to +120 °C
EPDM: -30 °C to +130 °C
Operating pressure:
0.5 to 16 bar
Media:
Compressed air, neutral gases, water, neutral light media, heating oil, other media on request
Installation position:
With upright solenoid
Voltages:
12V DC, 24V DC, 24V AC, 120V AC, 230V AC
Protection class:
IP65
Note:
Servo-operated valves require a pressure differential between the valve inlet and outlet to open or close. This pressure differential is specified as the minimum pressure. If pressure compensation occurs in the valve, possibly because there is no or very little consumption at the valve outlet, the valve will no longer operate reliably (open or close).
- Water flow at +20 °C, 1 bar pressure at the valve inlet, free outlet.
Air flow [l/min] approx. 13.4 × Kv × inlet pressure, when outlet pressure < inlet pressure / 2
(Inlet and outlet pressures are absolute values in bar.)
Specify protection class, NC valves only
Click here for more information about pneumatic valves