2/2-way stainless steel solenoid valve, NC, direct acting, G 1/8'', 230V AC, FKM

Article number: DMV22NC18FS230

Solenoid valve 2-2 stainless steel directly G1-8

2/2-way stainless steel solenoid valve, NC, direct acting, G 1/8'', 230V AC, FKM

Article number: DMV22NC18FS230

Documents for 2/2-way stainless steel solenoid valve, NC, direct acting, G 1/8'', 230V AC, FKM

icon2/2-way stainless steel solenoid valves, NC, direct-acting, DN3-8
Directly available

excl. VAT incl. VAT

Documents for 2/2-way stainless steel solenoid valve, NC, direct acting, G 1/8'', 230V AC, FKM

icon2/2-way stainless steel solenoid valves, NC, direct-acting, DN3-8

STANDARD SUPPLIED WITH PLUG

 

Materials:
Housing: Stainless steel
Seals: FKM, EPDM

 

Function:
Solenoid valve 2/2-way
Direct acting, normally closed (NC)

 

Thread:
G 1/8'', G 1/4'', G 3/8'' and G 1/2''

 

Nominal diameter (DN):
From 3 mm to 8 mm

 

Operating pressure:
0.5 to 16 bar
Note: depending on nominal diameter (DN)

 

Kv:
From 0.2 m³/h to 1.02 m³/h

 

Temperature range:
FKM: -10 °C to +120 °C
EPDM: -30 °C to +130 °C

 

Advantages:

  • Solenoid valves open and close very quickly compared to many other types of shut-off valves
  • Delivered including coil and connector
  • EPDM is suitable for (hot) water, neutral liquids, and many chemicals
  • Good environmental protection thanks to IP65 rating

 

Disadvantages:

  • Not suitable for low pressure differences (< 0.5 bar). For low pressure or vacuum, consider a (semi-) direct solenoid valve or another valve type such as an electric ball valve
  • EPDM is not suitable for oils and greases
  • Solenoid valves are very sensitive to dirt and can only be used with clean liquids and gases
  • Solenoid valves consume energy when activated and the coil can become hot. To dissipate heat, proper ventilation of the installation environment is recommended

 

Click here for more information about pneumatic valves

All statements are intended as non-binding guidelines! We are not liable for data selection not confirmed in writing. Pressure data, unless stated otherwise, relate to liquids from group II at +20 C.

TECHNICAL DATA

Operation

Normally closed

Actuation

Direct

Minimum temperature

-10 °C

Maximum temperature

120 °C

Thread

G 1/8"

Material

Stainless steel (RVS)

Seal

FKM

Voltage

230V AC

Nominal diameter (DN)

3 mm

Kv value

0.2 m³/h

Minimum pressure

0 bar

Maximum pressure

13 bar

Weight grams each
Commodity code84812090