IconEnglish

2/2-way solenoid valve, NC, G 3/4", 24V DC, NBR

Article number: M23424VDC

2-2 road valve G 3/8 "

2/2-way solenoid valve, NC, G 3/4", 24V DC, NBR

Article number: M23424VDC

Documents for 2/2-way solenoid valve, NC, G 3/4", 24V DC, NBR

icon2/2-way solenoid valves, NC/NO, pilot-operated, DN13-50
Directly available

excl. VAT incl. VAT

Documents for 2/2-way solenoid valve, NC, G 3/4", 24V DC, NBR

icon2/2-way solenoid valves, NC/NO, pilot-operated, DN13-50

STANDARD SUPPLIED WITH PLUG

 

Materials:
Housing: Brass
Internal parts: Brass / Stainless steel
Seals: NBR, FKM, EPDM

 

Function:
Solenoid valve 2/2-way or 3/2-way
Pilot-operated, normally closed (NC) or normally open (NO)

 

Nominal diameter (DN):
From 13 mm to 50 mm

 

Thread:
G 1/4″, G 3/8″, G 1/2″, G 3/4″, G 1″, G 1 1/4″, G 1 1/2″ and G 2″

 

Operating pressure:
0,3 to 16 bar
Note: depending on nominal diameter (DN)

 

Temperature range:
-10 °C to max. +85 °C

(types with G 1/8" and G 1/4": -10 °C to max. +130 °C)
Ambient: -10 °C to max. +50 °C

 

Media:
Compressed air, neutral gases, water, neutral light media, heating oil, other media on request

 

Installation position:
With upright solenoid

 

Voltages:
Standard: 24 V DC, 230 V AC
Optional: other voltages on request

 

Protection class:
IP65

 

Optional on request:
FKM seal (-10 °C to max. +130 °C) -V
EPDM seal for air and hot water (-10 °C to max. +120 °C) -EP
Explosion-proof** -EX

 

Note:
Servo-operated valves require a pressure difference between the valve inlet and outlet for opening or closing. This pressure difference is specified as minimum pressure. If pressure compensation occurs in the valve, possibly because there is little or no consumption at the valve outlet, the valve will no longer operate reliably (open or close).

  • Water flow at +20 °C, 1 bar pressure at the valve inlet, free outlet.
    Air flow [l/min] approx. 13.4 × Kv × inlet pressure, when outlet pressure < inlet pressure / 2
    (Inlet and outlet pressures are absolute values in bar.)
    Specify protection class, NC valves only


Click here for more information about pneumatic valves

All statements are intended as non-binding guidelines! We are not liable for data selection not confirmed in writing. Pressure data, unless stated otherwise, relate to liquids from group II at +20 C.

TECHNICAL DATA

Thread

G 3/4"

Voltage

24V DC

Operating pressure

0.3-16 bar

Function

2/2 NC

Orifice (DN)

21 mm

Seal

NBR

Length (L)

82 mm

kv value

100 L/min.

Weight grams each
Commodity code84812090