IconEnglish

Pressure gauges: tips from the specialist

PNEUPARTS.COM
Pressure gauges: tips from the specialist

Pressure gauges: tips from the specialist

 

"Measuring small pressure differences? Choose a digital sensor.

Analog pressure gauges are great for daily use: they are robust, require no battery or external power supply, and show at a single glance at the dial whether a system is pressurized.

Measuring high precision or small pressure differences? Go digital; the sensor registers fluctuations faster and more accurately than a mechanical movement. Whereas an analog scale quickly leaves you guessing between two graduation marks (and also exposes you to reading errors depending on your viewing angle), a digital display immediately shows the exact value down to the decimal point. Moreover, many digital models automatically store peaks and lows, allowing you to detect subtle pressure drops or leakage losses even when you are not standing next to the installation."



Read the full blog here

   

 

 

"Choose a pressure gauge whose operating pressure lies in the middle of the scale.

Choose a pressure gauge whose operating pressure lies in the middle of the scale. Pressure peaks exceeding the maximum range can permanently deform the internal mechanism, causing the gauge to no longer read accurately.

When this happens, the measuring element no longer returns to the zero position and the pointer will display an inaccurate reading from then on. By measuring in the middle of the scale. For example, a gauge up to 10 or 16 bar for an operating pressure of 6 to 8 bar, you don't only have a safe buffer for sudden pressure surges when switching on a pump or compressor, but you also benefit from the highest measurement accuracy."

Read the full blog here

  Manometer aansluiten: veilig kiezen en monteren  

 

 

"By inspecting regularly, you prevent deviations.

Unnoticed deviations cause malfunctions, for instance because valves are incorrectly adjusted or components are unknowingly overloaded.

Inspect pressure gauges annually and let them acclimatize first for a reliable measurement. Temperature differences cause metal measuring elements inside the pressure gauge to expand or contract slightly, which directly affects the pointer position. By letting the instrument reach ambient temperature first in a stable setup, you can be sure you are measuring the actual process pressure rather than a temperature deviation."

Read the full blog here
  Manometer aansluiten: veilig kiezen en monteren  

 

 

"Never tighten a pressure gauge by its housing.

Always use appropriate tools on the wrench flats. Make sure the system is completely depressurized and wrap PTFE tape in the direction of the thread for a leak-free seal without damage.

Applying force to the housing itself deforms the connection between the case and the delicate measuring mechanism inside, leading directly to measurement deviations or leaks. Furthermore, wrapping the tape in the direction of the thread prevents it from bunching up during installation and keeps the end of the thread free, ensuring no loose pieces of tape end up in your pipes or valves."

Read the full blog here
  Manometer aansluiten: veilig kiezen en monteren  

 

 

"With a dual scale, pay close attention to whether you are reading bar or PSI.

We often see that confusion go wrong. Always look straight at the dial and check the exact value of each graduation step before drawing conclusions about the system pressure.

Since 1 bar equals approximately 14.5 PSI, a quick glance at the wrong scale ring can easily make you think an installation is dangerously over-pressurized (or far too low). Standing directly in front of the gauge also prevents parallax error (an apparently shifted pointer caused by an angled view), ensuring you use the correct value when adjusting your pressure reducing valve pressure regulator or pressure switch."

Read the full blog here
   

 

 

"Do not confuse a pressure gauge and a barometer with each other.

For pipe pressure, vessels, and compressed air, choose a pressure gauge. 

A barometer strictly measures outside air and does not provide a usable value for your technical process in a closed system. Whereas a barometer only registers fluctuations in atmospheric air pressure around 1 bar (approx. 1013 hPa), a standard pressure gauge measures gauge pressure (overpressure) relative to that outside air. Moreover, a barometer does not have a pressure connection to safely mount onto a pipe or compressed air receiver; the instrument is built solely to measure ambient air, not to handle system pressure."

Read the full blog here
   

 

 

"Do not focus solely on the pressure reading on your pressure gauge.

Good pressure does not automatically mean sufficient flow.

When in doubt, always measure the flow rate as well and choose a gauge with the right range for an accurate reading. A pinched pipe or clogged filter will still neatly show the full system pressure when idle, but as soon as you switch on a machine or nozzle, capacity immediately plummets. By checking both the pressure and the flow rate in liters per minute, you can immediately see whether you are dealing with a pressure issue or a resistance issue in your piping network."

Read the full blog here
   

 

 

 